arp:StAdjEp
The ARP static adjacency endpoint, which is the endpoint object that contains information regarding statically configured endpoints. This is a statically configured endpoint corresponding to an interface.
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
ip | address:Ip |
Address | Value must match ipv4 or ipv6 known format |
mac | address:MAC |
MAC | Value must match MM:MM:MM:SS:SS:SS format |
name | naming:Name256 (string:Basic) |
The name of the object. | MAX SIZE: 63 |
Operational Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
operSt | arp:StAdjOperSt (scalar:Enum8) |
Operational State | SELECTION: 0 - down 1 - up 10 - unspecified DEFAULT: unspecified |
operStQual | arp:StAdjOperStQual (scalar:Enum8) |
Operational State Qualifier | SELECTION: 0 - unspecified 1 - subnet-mismatch 2 - invalid-mac 3 - invalid-ip 4 - invalid-vrf 5 - own-mac 6 - if-down 7 - up 8 - invalid-if 9 - invalid-clidata 10 - no-memory DEFAULT: unspecified |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |